RAID Setup
RAID Controller: |
3ware 9650SE |
RAID Level: |
RAID0 256K |
Disks: |
4 x Western Digital RE3 500 GB |
|
Write Cache Setting: |
Enabled |
Read Cache Setting: |
Intelligent |
Drive Queuing Mode: |
Enabled |
StorSave Profile: |
Balanced |
dd if=/dev/sda of=/dev/null bs=1M count=16000
16777216000 bytes (17 GB) copied, 36.4743 s, 460 MB/s
dd if=/dev/zero of=/dev/sda bs=1M count=16000
16777216000 bytes (17 GB) copied, 36.6236 s, 458 MB/s
parted /dev/sda mklabel msdos
parted /dev/sda mkpart p 2048s 128g
mkfs.ext3 -b 4096 -E stride=64 -E stripe-width=256 /dev/sda1
mount -o noatime /dev/sda1 /mnt
bonnie++ -d /mnt -u root -n 0
Version 1.96 ------Sequential Output------ --Sequential Input- --Random-
Concurrency 1 -Per Chr- --Block-- -Rewrite- -Per Chr- --Block-- --Seeks--
Machine Size K/sec %CP K/sec %CP K/sec %CP K/sec %CP K/sec %CP /sec %CP
finnix 12G 567 99 249938 45 121427 20 1894 94 428526 34 799.4 17