RAID Setup
RAID Controller: |
3ware 9650SE |
RAID Level: |
RAID10 256K |
Disks: |
4 x Western Digital RE3 500 GB |
|
Write Cache Setting: |
Enabled |
Read Cache Setting: |
Intelligent |
Drive Queuing Mode: |
Enabled |
StorSave Profile: |
Balanced |
dd if=/dev/sda of=/dev/null bs=1M count=16000
16777216000 bytes (17 GB) copied, 71.311 s, 235 MB/s
dd if=/dev/zero of=/dev/sda bs=1M count=16000
16777216000 bytes (17 GB) copied, 72.8608 s, 230 MB/s
parted /dev/sda mklabel msdos
parted /dev/sda mkpart p 2048s 128g
mkfs.ext3 -b 4096 -E stride=64 -E stripe-width=128 /dev/sda1
mount -o noatime /dev/sda1 /mnt
bonnie++ -d /mnt -u root -n 0
Version 1.96 ------Sequential Output------ --Sequential Input- --Random-
Concurrency 1 -Per Chr- --Block-- -Rewrite- -Per Chr- --Block-- --Seeks--
Machine Size K/sec %CP K/sec %CP K/sec %CP K/sec %CP K/sec %CP /sec %CP
finnix 12G 560 99 166177 30 79475 13 1899 95 225856 18 597.3 12
finnix 12G 550 99 164446 31 78881 13 1880 95 227057 19 799.9 16
finnix 12G 546 100 163233 31 79898 13 1925 97 226681 17 813.4 17