RAID Setup
RAID Controller: |
HighPoint RocketRAID 3510 |
RAID Level: |
RAID0 256K |
Disks: |
4 x Western Digital Caviar Black 750 GB |
Cache Policy: |
Write-Back |
Read Ahead: |
Enabled |
Write Cache: |
Enabled |
NCQ: |
Enabled |
dd if=/dev/sda of=/dev/null bs=1M count=16000
16777216000 bytes (17 GB) copied, 45.6702 s, 367 MB/s
dd if=/dev/zero of=/dev/sda bs=1M count=16000
16777216000 bytes (17 GB) copied, 46.0582 s, 364 MB/s
mkfs.ext3 -b 4096 -E stride=64 -E stripe-width=256 /dev/sda1
mount -o noatime /dev/sda1 /mnt
bonnie++ -u root -f -n 0 -r 8000 -d /mnt
Version 1.96 ------Sequential Output------ --Sequential Input- --Random-
Concurrency 1 -Per Chr- --Block-- -Rewrite- -Per Chr- --Block-- --Seeks--
Machine Size K/sec %CP K/sec %CP K/sec %CP K/sec %CP K/sec %CP /sec %CP
finnix 16G 290653 59 123435 20 331633 20 590.4 12
Latency 326ms 126ms 154ms 493ms