RAID Setup
RAID Controller: |
HighPoint RocketRAID 3510 |
RAID Level: |
RAID10 512K |
Disks: |
4 x Western Digital Caviar Black 750 GB |
Cache Policy: |
Write-Back |
Read Ahead: |
Enabled |
Write Cache: |
Enabled |
NCQ: |
Enabled |
dd if=/dev/sda of=/dev/null bs=1M count=16000
16777216000 bytes (17 GB) copied, 90.113 s, 186 MB/s
dd if=/dev/zero of=/dev/sda bs=1M count=16000
16777216000 bytes (17 GB) copied, 90.2481 s, 186 MB/s
mkfs.ext3 -b 4096 -E stride=128 -E stripe-width=256 /dev/sda1
mount -o noatime /dev/sda1 /mnt
bonnie++ -u root -f -n 0 -r 8000 -d /mnt
Version 1.96 ------Sequential Output------ --Sequential Input- --Random-
Concurrency 1 -Per Chr- --Block-- -Rewrite- -Per Chr- --Block-- --Seeks--
Machine Size K/sec %CP K/sec %CP K/sec %CP K/sec %CP K/sec %CP /sec %CP
finnix 16G 145113 30 69649 11 179053 11 756.2 16
Latency 448ms 235ms 312ms 99457us